Products
Transformer Tester
HV Testing Equipment
Series Resonant Equipment
Secondary Circuit Tester
Cable/Lightening Arrester Tester
Earth/Insulation Series
Electrical Measurement & Transformer
Other Electrical Tester
test1
test2
test3
test4
Recommended Products
Contact Us
  • ADD:China Wuhan East Lake hi tech Development Zone (Optics Valley of China)
    TEL:+86 400-6884446
    FAX:+86 400-6884446
    E-mail:whguozi@163.com

GOZ-GTB Series AC Hipot Test Set (Power Frequency Withstand Voltage Test Set)

GOZ-GTB Series AC Hipot Test Set (Power Frequency Withstand Voltage Test Set)
  • Series AC Hipot Test Set (Power Frequency Withstand Voltage Test Set)
Product Description
   This instrument is also known as the booster, it is the essential device for power generation and supply equipment test, various electrical products test and electric strength test of insulation materials. 
   AC Hipot Test Set (Power Frequency Withstand Voltage Test Set) series produced by our company completely overcome the old-fashioned' shortcoming that it is bulky, heavy. Equipped with high-voltage silicon stack produced by our company, the instrument can provide DC high voltage test power supply. Together with the control cabinet (desk), automatic protection micro-ammeter, sphere gap and so on, the instrument especially suits for on-site test and it makes the heavy work become convenient, fast, easy, flexible, and more efficient. Therefore, it is highly praised and appreciated by the customers coming from power systems and large-scale factory and mining enterprises.
Alternative Name
    HV testing transformer, HV booster, high voltage tester
 
Product illustrations
 
Product Features
 1. samll in volume, light in weight, compact structure, oil-tight, without maintenance. 
2. easy to connect wire , convenient to use.
3. stable for insulation, with beautiful appearance.
4. with the function of overvoltage protection.
Product parameters
1. Impedance voltage: ≤ 12%
2. Output voltage waveform: sine wave
3. surface temperature rise: < 55 ℃
4. No-load current: < 4%
5. Allowable continuous running time: 1 hour
6. main product parameters
 

Model

Capacity

Input voltage

Output voltage

Output current

Output DC high voltage

Weight

( kVA )

( V )

( kV )

( mA )

( kV )

( kg )

1.5/50

1.5

200
or 
400

50

30

70

15

3/50

3

60

20

5/50

5

100

30

10/50

10

200

40

15/50

15

300

50

20/50

20

400

55

25/50

25

500

60

30/50

30

600

65

5/100

5

200
or 
400

100

50

140

60

10/100

10

100

65

15/100

15

150

70

20/100

20

200

75

25/100

25

250

80

15/120

15

120

125

 

85

20/120

20

160

 

90

25/120

25

200

 

95

30/120

30

250

 

100

Notes: non-standard parameter or parameters not in the table please refer to data plate.