GOZ-CR Lightning Pulse Capacitive Voltage Divider

GOZ-CR Lightning Pulse Capacitive Voltage Divider
  • Lightning Pulse Capacitive Voltage Divider
Product Description
    GOZ-CR lightning pulse capacitive voltage divider is mainly used for lightning wave measurement, voltage measurement of power frequency and impulse high voltage, including lightning wave, 8/20us wave and other lightning waveform. Connected to network, it is also carried out online monitoring for the lightning overvoltage. As a special lightning wave divider, it has advantages such as simple operation, intuitive display, high precision, small size, light weight and so on. The divider is ideal equipment for lightning wave measurement, applied to grid primary equipment type test (such as zinc oxide arrester lightning steep wave test, e voltage transformer lightning full wav test, high voltage switch lightning full wave test, substation main transformer type test, high voltage GIS test, etc.), substation, high voltage electrical equipment manufacturing factory and high voltage laboratory and other departments. GOZ Technology can meet requirements like China State Grid Electricity Power Research Institute and other relevant authorities inspection, and issue a partial discharge ultrasonic positioning system test report.
    GOZ-CR lightning pulse capacitive voltage divider can be connected to power grid long-term operation, which meets the following lightning pulse waveform monitoring: standard lightning impulse full waveform, standard lightning impulse chopped waveform, standard operation impact full wave voltage waveform, steepness >1000kV/μs waveform and steepness > 2500kV/μs waveform. When carrying out impact measurement, it can be used as load capacitance, and also composed of chopping equipment with chopping gaps combination. 
    Also called:Lightning high voltage pulse divider, lighting impact high voltage impulse divider, impact voltage impulse divider, overvoltage monitoring divider, resistive & capacitive voltage divider, capacitive divider 
Product illustrations
 
Product Features
 1. High voltage measurement range: 0 ~ 300kV / 0 ~ 400kV; max. is lightning impulse voltage; 
2. Suitable for 1 ~ 35kV power distribution system high voltage transmission line lightning online monitoring; 
3. Impulse bandwidth: 30MHz, lightning head response resolution < 100ns, that is <0.1us;
4. Secondary measurement interface: metal shield shell, 50Ω or 75Ω matched impedance, Coaxial cable connector output;
5. Primary high voltage side interface: all metal platen, connecting the electrical bus with fastening bolt; single-phase direct connection; 6:. ± 1%
6. Non-linearity degree:±1%;
7. Measurement uncertainty:±1%;
8. Outdoor operating environment: outdoor work, water-proof, moisture-proof, high temperature resistant, cold resistant and high altitude resistant; outdoor installation; 
9. Needed to collect lightning over-voltage and power frequency overvoltage, while the working frequency range is 35Hz ~ 5MHz; 
10. Long time network connects operation, with synthetic silicone rubber casing insulating housing. Meet on-line monitoring of lightning pulse waveform.
11. When used for frequency or DC measurement, it can continuously run two hours at the rated voltage. 
12. Capacitor capacity and partial voltage ratio deviation range: ± 5%.
13. Capacitor dielectric loss tangent, pure capacitive voltage divider, under 20 ℃, 0.4-0.5UN, tgδ≤0.0025, while resistive voltage divider tgδ value is not specified. 
14. Impulse voltage measuring divider and other components as a system, the square wave response should be consistent with requirements of GB311-83 4.4.2.
15. Above 1000m, or temperature and humidity out of the requirements of article 3, please customize or reduce the suing voltage.
 
Product parameters
 

No.

Model

Rated voltageKV

Nominal capacitancePF

Rated partial voltage ratio

Features & function

Altitudemm

Weightkg

1

100-1000

100

1000

200

Frequency, impact

600

14.5

2

200-60

AC-200

60

1000

Parallel resistance  and capacitance, frequency, no halo

1200

28

3

200- 1000

AC- 200

1200

3000

Frequency measurement, no corona

1300

30

4

300-400

AC-300

400

1500

Frequency, impact

1800

39

5

400- 800

400

800

500

Low damping, Impact measurement

1400

34

6

250-500

250

500

1000

Frequency, Impact measurement

1760

38

7

500-1000

500

1000

1000

Impact measurement

1400

34

8

600-1000

600

1000

1000-2000

Impact measurement

1550

36

9

800-500

800

500

1000- 2000

Impact measurement

2250

42

10

800-600

800

600

1000-2000

Impact measurement, Chopping equipment

2200

52

11

1200- 400

1200

400

2000-3000

Impact measurement, Chopping equipment

3200

76

12

2400-500

2400

500

3000- 6000

Impact measurement, Chopping equipment

5660

140

13

300-500

AC-300

500

3000

Frequency measurement, no corona

2370

50

14

200- 1000

AC- 200

1000

1000

Frequency measurement

1650

40

15

250-1000

AC-250

1000

1000

Frequency measurement

2400

60

16

500-1000

AC-500

1000

1000

Frequency measurement

1300

180

17

750-0.001

750

1000

7500

Frequency measurement

5500

 

18

1000-0.0005

1000

500

10000

Frequency measurement

7500