Products
Transformer Tester
HV Testing Equipment
Series Resonant Equipment
Secondary Circuit Tester
Cable/Lightening Arrester Tester
Earth/Insulation Series
Electrical Measurement & Transformer
Other Electrical Tester
test1
test2
test3
test4
Recommended Products
Contact Us
  • ADD:China Wuhan East Lake hi tech Development Zone (Optics Valley of China)
    TEL:+86 400-6884446
    FAX:+86 400-6884446
    E-mail:whguozi@163.com

GOZ-SMG2000E Clamp Phase Meter

GOZ-SMG2000E Clamp Phase Meter
  • Clamp Phase Meter
Product Description
     SMG20000E Clamp Phase Meter is special designed for voltage, current and phase tests, it is in high-precision, low price, portable hand-held, dual-channel input measuring. It's easy to measure the phase between U-U, I-I and U-I, identify the inductive circuit ,capacitive circuit and the phase sequence of three-phase voltage, detect the wiring group of transformer, test the secondary circuit and bus differential protection system, display the phase relationship among the CT groups of a differential protection system, and check if the wire of electric meter was correctly connected. When testing customers do not need cut off the tested current which input by clamp-current transformer. When measuring the phase between U1 and U2, the two input circuit loop are completely isolated, so the possible misconnection is absolutely avoided, which may result in short circuit and may even burn the meter. The monitor of the device is high-contrast LCD screen, and the character in big size, which helps to obtain the best visual effects.
Alternative Name
     phase meter, LV phase meter, double clamp digital phase meter
Product illustrations
 
Product Features
 1. ingenious structure, easy to operate.
   a. hand held structure
   b. you should not disconnect the circuit or change the measurement range under 10mA-10A , 3V-500v.
   c. use high contrast LCD, character can be 25mm, the screen angle can be 700, to obtain the best visual effects
   d. the function and layout of the switch are reasonable, rotating can read the measuring voltage ,current and phase.
2. high resolution
   adopt new type patent current clamp , current resolution up to 0.1mA; voltage resolution up to 0.1V.
3. Low power consumption
   this product with micro power consumption design and with the function of testing the voltage of battery.
Product parameters
 Intrinsic Error

1. Reference Operating Conditions
  (1) Temperature:(23
±5)
  (2) Moisture:(45
75)% RH
  (3) Wave forms of measured signal:sine wave
、β=0.02
  (4) Frequency of measured signal:(50
±0.2)Hz
  (5) Position of Measured current carrying conductor in the nipper jaw:Optional position
  (6) Amplitude range of measured signal when measuring phase:
      100
220V0.5A1.5A
  (7) External reference frequency electromagnetic interference: Should be avoided
2. Limits of Intrinsic Error
  (1) AC Voltage(see Table 1)

Table 1:Error of AC Voltage

Measure range

Resolution

Limits of intrinsic error

20V

0.01V

±(.3%RD+0.2% Range)

200V

0.1V

±(0.3%RD+0.2% Range)

500V

1V

±(0.3%RD+0.2% Range)

      Input Impedance:All the measure range is 2MΩ
      Voltage input impedance of phase testing: >500K
Ω
  (2) Alternating current(see Table 2)

Table 2:Error of alternating current

Measure range

Resolution

Limits of intrinsic error

200mA

0.1mA

±(0.3%RD+0.2)

2A

1mA

10A

10mA

  (3) Phase
      U-U
U-II-I(see Table 3)

Table 3: Error of Power-frequency Phase

Range

Resolution

Limits of intrinsic error

0360°

1°

±2°

      Impedance of input voltage loop when measuring phase of U1-U2:40KΩ
Operating error
1. Rated Operating Conditions
  (1) Temperature:040
  (2) Moisture:
90%v
  (3) Wave forms of measured signal:sine wave
、β=0.05v
  (4) Frequency of measured signal:(50
±0.5)Hz
  (5) Position of Measured current carrying conductor in the nipper jaw:Optional position.
  (6) Amplitude range of measured signal when measuring phase:v Phase U1-U2:30V
500V
      Phase I1-I2:10mA
10.00A
      Phase U1-I2 or I1-U2:10V500V10mA10.00A
  (7) External reference frequency electromagnetic interference: should be avoidedv 2 . Limits of Rated Operating Error
    Under the conditions described in 1, the limits of the rated operating error will not exceed twice of the limits of intrinsic error.
Other technical features
1. Display:three and half
2. Sampling Rate:3 times per second
3. Power Supply:Single 9V laminated cell
current of power is less than 5mA
4. Dimension
   Meter shell: 186x86x33mm
   Nipper shell: 140mm
×40mm×19mm
   Nipper jaw: Φ7mm×8mm
5. Weight
   Meter body: 280g
   Measuring pliers:2
×200g
6. Storage Conditions
   Temperature:
1050