GOZ-FY Transformer Load Box

GOZ-FY Transformer Load Box
  • Transformer Load Box
Product Description
      FY series current, voltage transformer load box supply various real load when test current or voltage transformer, it is the ideal auxiliary product for transformer detectors. It is strictly designed according JJG313-94 ,JJG314-94 , it is with advantages of large output capacity, great variety of load, light weight, beautiful outlook, strong stability, etc.
Alternative Name
    transformer load box ,CT load box, PT load box
Product illustrations
 
Product Features
 Light weight, beautiful outlook, high capacity and strong stability,
Product parameters
 1. FY96-H current transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃) 
   humidity: < 1500m        frequency:50Hz 
   rated capacity: COS0.8: 2.5VA-60VA;  COS1.0: 2.5VA-20VA;
   measurement range:
   current: 1%-120%
   secondary current:5A
   power factor:0.8, 1.0
   accuracy: ±3%±0.0025VA
   test voltage:2KV
   dimension: 250 mm×350 mm×175 mm
   weight:8kg
2. FY96-A current transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃)
   humidity: < 1500m        frequency:50Hz
   rated capacity: COS0.8: 2.5VA-60VA;  COS1.0: 2.5VA-20VA;
   measurement range:
   current: 5%-120%
   secondary current:1A
   power factor:0.8, 1.0
   accuracy: ±3%±0.0025VA
   test voltage:2KV
   dimension: 250mm×350mm×175mm
   weight:8kg
3. FY95-H voltage transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃)
   humidity: < 1500m        frequency:50Hz
   rated capacity: 1.25VA-158.75VA
   measurement range:20%-120%
   secondary voltage:110/ V 
   power factor:0.8, 1.0
   accuracy: ±3%±0.05VA
   test voltage:2KV
   dimension: 250mm×350mm×175mm
   weight:8kg
4. FY95-A voltage transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃)
   humidity: < 1500m        frequency:50Hz
   rated capacity: 1.25VA-158.75VA
   measurement range:20%-120%
   secondary voltage:110/ V 
   power factor:0.8, 1.0
   accuracy: ±3%±0.05VA
   test voltage:2KV
   dimension: 250mm×350mm×175mm
   weight:8kg
5. FY98-H current voltage transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃)
   humidity: < 1500m        frequency:50Hz
   rated capacity: 
   current :COS0.8: 2.5VA-60VA;  COS1.0: 2.5VA-5VA;
   voltage: 1.25VA-158.75VA
   measurement range:
   current: 1%-120%      voltage: 20%-120%
   secondary current:1A    
   secondary voltage:110/ V 
   power factor:0.8, 1.0
   accuracy:
   current: ±3%±0.0025VA    voltage: ±3% ±0.05VA
   test voltage:2KV
   dimension: 340mm×350mm×175mm
   weight:15kg
6. FY98-A current voltage transformer load box
   Main technique parameters
   condition of circumstance 
   temperature: 15-25℃     humidity: <80%(25℃)
   humidity: < 1500m        frequency:50Hz
   rated capacity: 
   current :COS0.8: 2.5VA-60VA;  COS1.0: 2.5VA-5VA;
   voltage: 1.25VA-158.75VA
   measurement range:
   current: 5%-120%      voltage: 20%-120%
   secondary current:1A    
   secondary voltage:110/ V 
   power factor:0.8, 1.0
   accuracy:
   current: ±3%±0.0025VA    voltage: ±3% ±0.05VA
   test voltage:2KV
   dimension: 340mm×350mm×175mm
   weight:15kg