1.The device has high sensitivity, wide range of sample capacity coverage, full equipped input unit (detection impedance) and multi-band combinations (nine kinds).
2.The device can directly read the amount of pulse discharge after properly calibration.
3.The device uses a color LCD screen display which differs from the traditional CRT, for it is easy to observe and analysis with a waveform lock function.
1.Using Condition
Temperature: 0~40℃±2℃
Relative humidity: < 80%
Supply power: 220V±22V, 50Hz
No severe vibration and mechanical shock.
Air does not contain enough dust which may corrode device
Should not be affected by strong electromagnetic interference.
Good ventilation.
Grounding requirements: grounding resistance <1Ω.
2.Tested product capacitance range: 6PF--250μF
3.Test Sensibility(check table 1)
Table 1
Input unit No. Tuning Capacitor Unit Sensibility (rrC)
(asymmetric circuit)
1 6-25-100 pF 0.02
2 25-100-400 pF 0.04
3 100-400-1500 pF 0.06
4 400-1500-6000 pF 0.1
5 1500-6000-25000 pF 0.2
6 0.006-0.025-0.1 μF 0.3
7 0.025-0.1-0.4 μF 0.5
8 0.1-0.4-1.5 μF 1
9 0.4-1.5-6.0 μF 1.5
10 1.5-6.0-25 μF 2.5
11 6.0-25-60 μF 5
12 25-60-250 μF 10
7R Resistance 0.5
4. Amplifier band:
① Low-end: 10kHz, 20kHz, 40kHz optional
② High-end: 80kHz, 200kHz, 300kHz optional
5. Amplifier gain adjustment:
Coarse six stall, between stalls gain 20±1db; fine range >20db.
6. Time window:
① Time window displayed in yellow
② Window width: adjustable range 15 ° ~ 150 °
③ Window position: each window can be rotated 0 ° ~ 170 °
④ Two time windows can be opened separately or simultaneously
7. Discharge scale:
Digital meter: showed 3½LED digital meter
0-100.0 error <± 5% (at full scale caculated)
8. Oval time base:
Frequency 50Hz and arbitrary frequency
Oval displayed in blue
Elliptical rotation: 30 °as a file, can have 180 ° rotation
Display: Oval - Linear
High frequency oval time base input voltage <220V, its uptake power <1 VA
9. Waveform lock: can lock any time desired waveform which is easy to observe and analyze
10. Voltmeter test:
① Range: 100kV (extensible)
② Display: 3½ digital voltmeter indication
③ Accuracy: better than ± 5% (at full scale caculated)
11. Internal or external zero mark function
12. Size: 450 * 450 * 190 (W * D * H) mm3
13. Weight: about 15kg